Analytical Liquid Chromatography System LC3000

Precision: ◆ traffic range is 0.001-9.999ml/min, incremental 0.001ml/min, which can achieve long-term separation effect of low traffic. ◆ optimized cam curve and ten-point flow correction control the flow accuracy to ±0.5% and RSD ≤ 0.1% to ensure stable and accurate solvent delivery. ◆ can be configured with degasser to degassing online to avoid solvent bubbles affecting the experimental results. ◆ high precision step control and new wavelength calibration method, wavelength accuracy up to ±0.1nm, combined with excellent performance of low baseline noise and drift, excellent spectral signal can be obtained. ◆ sample treatment is more accurate, supporting 0.1-200ul injection volume, the best precision < 0.25%RSD, so that the injection has high repeatability. ◆ < 0.005% extremely low cross contamination and optimized pipeline design ensure high separation of analytical chromatography. Easy to use: ◆ is equipped with self-developed EasyChrom chromatography software, and users can

Double-click to edit text content
Analytical Liquid Chromatography System LC3000
  • Analytical Liquid Chromatography System LC3000
0

Analytical Liquid Chromatography System LC3000

Infusion System

Double piston series mode, floating piston design

Flow Range

0.001~9.999ml/min, Increment 0.001ml/min

Flow Accuracy

±0.5%

Flow Repeatability

RSD≤0.1%

Pressure Pulsation

≤0.3Mpa

Pressure Range

≤42Mpa(316L Stainless Steel Pump Head)

Tray Type

120x2mL Sample Vial;2x96 Orifice Plate

Injection Volume

0.1-200ul(Increment 0.1ul)

Injection Precision

1%RSD(@Below 2uL, Specific Test Conditions)

0.25%RSD(@Above 2uL, Specific Test Conditions)

Injection Accuracy

±0.5%(50uL)

Linearity

>0.9998

Residual Effect

0.005%(Perform Cleaning Procedure Before and after Sample Injection)

Detection System

190-800nm Wavelength, Single and Dual Wavelength Mode Optional

Wavelength Range

190nm-800nm, Increment 1nm,Deuterium lamp Tungsten lamp Optional

Wavelength Accuracy

1nm

Wavelength Precision

±0.1nm

Baseline Noise

±0.5×10-5 AU

Baseline Drift

2×10-4 AU

Flow Cell Type

10μl

Detection Range

0-2Au

Control

Instrument Panel Control or Computer Counter-control

Power

100~240VAC, 50/60Hz


Analytical Liquid Chromatography System LC3000

Infusion System

Double piston series mode, floating piston design

Flow Range

0.001~9.999ml/min, Increment 0.001ml/min

Flow Accuracy

±0.5%

Flow Repeatability

RSD≤0.1%

Pressure Pulsation

≤0.3Mpa

Pressure Range

≤42Mpa(316L Stainless Steel Pump Head)

Tray Type

120x2mL Sample Vial;2x96 Orifice Plate

Injection Volume

0.1-200ul(Increment 0.1ul)

Injection Precision

1%RSD(@Below 2uL, Specific Test Conditions)

0.25%RSD(@Above 2uL, Specific Test Conditions)

Injection Accuracy

±0.5%(50uL)

Linearity

>0.9998

Residual Effect

0.005%(Perform Cleaning Procedure Before and after Sample Injection)

Detection System

190-800nm Wavelength, Single and Dual Wavelength Mode Optional

Wavelength Range

190nm-800nm, Increment 1nm,Deuterium lamp Tungsten lamp Optional

Wavelength Accuracy

1nm

Wavelength Precision

±0.1nm

Baseline Noise

±0.5×10-5 AU

Baseline Drift

2×10-4 AU

Flow Cell Type

10μl

Detection Range

0-2Au

Control

Instrument Panel Control or Computer Counter-control

Power

100~240VAC, 50/60Hz