Precision: ◆ traffic range is 0.001-9.999ml/min, incremental 0.001ml/min, which can achieve long-term separation effect of low traffic. ◆ optimized cam curve and ten-point flow correction control the flow accuracy to ±0.5% and RSD ≤ 0.1% to ensure stable and accurate solvent delivery. ◆ can be configured with degasser to degassing online to avoid solvent bubbles affecting the experimental results. ◆ high precision step control and new wavelength calibration method, wavelength accuracy up to ±0.1nm, combined with excellent performance of low baseline noise and drift, excellent spectral signal can be obtained. ◆ sample treatment is more accurate, supporting 0.1-200ul injection volume, the best precision < 0.25%RSD, so that the injection has high repeatability. ◆ < 0.005% extremely low cross contamination and optimized pipeline design ensure high separation of analytical chromatography. Easy to use: ◆ is equipped with self-developed EasyChrom chromatography software, and users can
Analytical Liquid Chromatography System LC3000 | |
Infusion System | Double piston series mode, floating piston design |
Flow Range | 0.001~9.999ml/min, Increment 0.001ml/min |
Flow Accuracy | ±0.5% |
Flow Repeatability | RSD≤0.1% |
Pressure Pulsation | ≤0.3Mpa |
Pressure Range | ≤42Mpa(316L Stainless Steel Pump Head) |
Tray Type | 120x2mL Sample Vial;2x96 Orifice Plate |
Injection Volume | 0.1-200ul(Increment 0.1ul) |
Injection Precision | <1%RSD(@Below 2uL, Specific Test Conditions) <0.25%RSD(@Above 2uL, Specific Test Conditions) |
Injection Accuracy | ±0.5%(50uL) |
Linearity | >0.9998 |
Residual Effect | <0.005%(Perform Cleaning Procedure Before and after Sample Injection) |
Detection System | 190-800nm Wavelength, Single and Dual Wavelength Mode Optional |
Wavelength Range | 190nm-800nm, Increment 1nm,Deuterium lamp Tungsten lamp Optional |
Wavelength Accuracy | 1nm |
Wavelength Precision | ±0.1nm |
Baseline Noise | ±0.5×10-5 AU |
Baseline Drift | 2×10-4 AU |
Flow Cell Type | 10μl |
Detection Range | 0-2Au |
Control | Instrument Panel Control or Computer Counter-control |
Power | 100~240VAC, 50/60Hz |
Analytical Liquid Chromatography System LC3000 | |
Infusion System | Double piston series mode, floating piston design |
Flow Range | 0.001~9.999ml/min, Increment 0.001ml/min |
Flow Accuracy | ±0.5% |
Flow Repeatability | RSD≤0.1% |
Pressure Pulsation | ≤0.3Mpa |
Pressure Range | ≤42Mpa(316L Stainless Steel Pump Head) |
Tray Type | 120x2mL Sample Vial;2x96 Orifice Plate |
Injection Volume | 0.1-200ul(Increment 0.1ul) |
Injection Precision | <1%RSD(@Below 2uL, Specific Test Conditions) <0.25%RSD(@Above 2uL, Specific Test Conditions) |
Injection Accuracy | ±0.5%(50uL) |
Linearity | >0.9998 |
Residual Effect | <0.005%(Perform Cleaning Procedure Before and after Sample Injection) |
Detection System | 190-800nm Wavelength, Single and Dual Wavelength Mode Optional |
Wavelength Range | 190nm-800nm, Increment 1nm,Deuterium lamp Tungsten lamp Optional |
Wavelength Accuracy | 1nm |
Wavelength Precision | ±0.1nm |
Baseline Noise | ±0.5×10-5 AU |
Baseline Drift | 2×10-4 AU |
Flow Cell Type | 10μl |
Detection Range | 0-2Au |
Control | Instrument Panel Control or Computer Counter-control |
Power | 100~240VAC, 50/60Hz |